Skip to main content

Fluorimetric Determination of Febuxostat in Dosage Forms and in Real Human Plasma via Förster Resonance Energy Transfer

Research Abstract
A rapid, simple, selective and precise fluorimetric method was developed and validated for determination of a selective xanthine oxidase inhibitor; febuxostat (FBX) in pharmaceutical formulations and in human plasma. The proposed method is based on quenching effect of FBX on the fluorescence intensity of terbium (Tb3+) through fluorescence resonance energy transfer (FRET) from Tb3+ to FBX. The formed complex was measured at λex. 320 nm/λem. 490 nm against a reagent blank. Fluorescence intensity of Tb3+ was diminished when FBX was added. A linear relationship between the fluorescence quenching value of the formed complex (ΔF = FTb3+ − FFBX−Tb3+) and the concentration of FBX was investigated. The reaction conditions and the fluorescence spectral properties of the complex have been studied. The linearity range of the developed method was 1.0–16.0 μg/ml. The suggested method was applied successfully for the estimation of FBX in bulk powder, dosage forms and spiked plasma samples with excellent recoveries (96.79–98.89%). In addition, the developed method has been successfully applied for determination of FBX in real plasma samples collected from healthy volunteers with good recoveries (82.06–85.65%). All obtained results of the developed method were statistically analyzed and validated according to ICH (International Conference on Harmonization) guidelines.
Research Authors
Samia M. El-Gizawy, Noha N. Atia, Noha M. Hosny
Research Journal
Luminescence, DOI: 10.1002/bio.3485
Research Member
Research Publisher
NULL
Research Rank
1
Research Vol
Vol. 33
Research Website
NULL
Research Year
2018

Fluorimetric Determination of Febuxostat in Dosage Forms and in Real Human Plasma via Förster Resonance Energy Transfer

Research Abstract
A rapid, simple, selective and precise fluorimetric method was developed and validated for determination of a selective xanthine oxidase inhibitor; febuxostat (FBX) in pharmaceutical formulations and in human plasma. The proposed method is based on quenching effect of FBX on the fluorescence intensity of terbium (Tb3+) through fluorescence resonance energy transfer (FRET) from Tb3+ to FBX. The formed complex was measured at λex. 320 nm/λem. 490 nm against a reagent blank. Fluorescence intensity of Tb3+ was diminished when FBX was added. A linear relationship between the fluorescence quenching value of the formed complex (ΔF = FTb3+ − FFBX−Tb3+) and the concentration of FBX was investigated. The reaction conditions and the fluorescence spectral properties of the complex have been studied. The linearity range of the developed method was 1.0–16.0 μg/ml. The suggested method was applied successfully for the estimation of FBX in bulk powder, dosage forms and spiked plasma samples with excellent recoveries (96.79–98.89%). In addition, the developed method has been successfully applied for determination of FBX in real plasma samples collected from healthy volunteers with good recoveries (82.06–85.65%). All obtained results of the developed method were statistically analyzed and validated according to ICH (International Conference on Harmonization) guidelines.
Research Authors
Samia M. El-Gizawy, Noha N. Atia, Noha M. Hosny
Research Journal
Luminescence, DOI: 10.1002/bio.3485
Research Member
Research Publisher
NULL
Research Rank
1
Research Vol
Vol. 33
Research Website
NULL
Research Year
2018

Determination of donepezil in spiked rabbit plasma by high-performance liquid chromatography with fluorescence detection

Research Abstract
The aim of this paper is to develop sensitive, accurate, reproducible and robust RP-HPLC with fluorescence detection for estimation of donepezil (DZ) in rabbit plasma using silodosin as the internal standard (IS). The prepared samples were quantified on reversed phase column Luna C18(2) (150 × 4.6 mm i.d., 5 µm particle size) operated at room temperature using the mobile phase consisting of methanol: 0.1% acetic acid (50 : 50, v/v) at a flow rate of 1 ml min−1. The method was fully validated according to bioanalytical validation guidelines of FDA in terms of system suitability, selectivity, sensitivity, precision and stability. It was found that the increase in peak areas followed the increase of DZ concentration in the range of 2.56–200.00 ng ml−1 with LOD of 0.85 ng ml−1. The method was successfully applied for the determination of DZ in rabbit plasma using manual shaking dispersive liquid–liquid microextraction.
Research Authors
Fardous A. Mohamed , Pakinaz Y. Khashaba , Reem Y. Shahin and Mohamed M. El-Wekil
Research Journal
Royal Society Open Science
Research Publisher
RSC
Research Rank
1
Research Vol
6
Research Website
NULL
Research Year
2019

Determination of donepezil in spiked rabbit plasma by high-performance liquid chromatography with fluorescence detection

Research Abstract
The aim of this paper is to develop sensitive, accurate, reproducible and robust RP-HPLC with fluorescence detection for estimation of donepezil (DZ) in rabbit plasma using silodosin as the internal standard (IS). The prepared samples were quantified on reversed phase column Luna C18(2) (150 × 4.6 mm i.d., 5 µm particle size) operated at room temperature using the mobile phase consisting of methanol: 0.1% acetic acid (50 : 50, v/v) at a flow rate of 1 ml min−1. The method was fully validated according to bioanalytical validation guidelines of FDA in terms of system suitability, selectivity, sensitivity, precision and stability. It was found that the increase in peak areas followed the increase of DZ concentration in the range of 2.56–200.00 ng ml−1 with LOD of 0.85 ng ml−1. The method was successfully applied for the determination of DZ in rabbit plasma using manual shaking dispersive liquid–liquid microextraction.
Research Authors
Fardous A. Mohamed , Pakinaz Y. Khashaba , Reem Y. Shahin and Mohamed M. El-Wekil
Research Journal
Royal Society Open Science
Research Publisher
RSC
Research Rank
1
Research Vol
6
Research Website
NULL
Research Year
2019

Determination of donepezil in spiked rabbit plasma by high-performance liquid chromatography with fluorescence detection

Research Abstract
The aim of this paper is to develop sensitive, accurate, reproducible and robust RP-HPLC with fluorescence detection for estimation of donepezil (DZ) in rabbit plasma using silodosin as the internal standard (IS). The prepared samples were quantified on reversed phase column Luna C18(2) (150 × 4.6 mm i.d., 5 µm particle size) operated at room temperature using the mobile phase consisting of methanol: 0.1% acetic acid (50 : 50, v/v) at a flow rate of 1 ml min−1. The method was fully validated according to bioanalytical validation guidelines of FDA in terms of system suitability, selectivity, sensitivity, precision and stability. It was found that the increase in peak areas followed the increase of DZ concentration in the range of 2.56–200.00 ng ml−1 with LOD of 0.85 ng ml−1. The method was successfully applied for the determination of DZ in rabbit plasma using manual shaking dispersive liquid–liquid microextraction.
Research Authors
Fardous A. Mohamed , Pakinaz Y. Khashaba , Reem Y. Shahin and Mohamed M. El-Wekil
Research Journal
Royal Society Open Science
Research Publisher
RSC
Research Rank
1
Research Vol
6
Research Website
NULL
Research Year
2019

Applications of Fourier transform infrared spectroscopic method for simultaneous quantitation of some hypoglycemic drugs in their binary mixtures

Research Abstract
Cost-effective, green, simple and reliable transmission Fourier-transform infrared (FTIR) spectroscopic method was developed for simultaneous analysis of hypoglycemic drugs in their binary mixtures for the first time. The FTIR method was applied for the determination of vildagliptin (VILD), glimepiride (GLIM) and pioglitazone (PIOG) in binary mixture with metformin (METF). The method was validated according to the International Conference on Harmonization (ICH) guidelines. The obtained results (expressed in peak areas) are linear with concentration in the range of 0.61–20, 0.26–24 and 0.37–4 μg/mg for VILD, PIOG and GLIM, respectively while the linearity ranges for METF were 0.40–200, 0.26–800 and 0.19–1000 μg/mg with VILD, PIOG and GLIM, respectively. The limits of detection (LODs) were 0.20, 0.08 and 0.12 μg/mg for VILD, PIOG and GLIM, respectively while METF LODs were 0.13, 0.08 and 0.06 μg/mg with VILD, PIOG and GLIM, respectively. The FTIR method has been successfully applied for the determination of the cited binary mixtures in its pharmaceutical tablets and the obtained results showed satisfactory % recovery.
Research Authors
Mohamed M.El-Wekil, Khaled K.Abdelhady, Randa A.Abdel Salam, Ghada M.Hadad
Research Journal
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Research Publisher
Elsevier
Research Rank
1
Research Vol
213
Research Website
NULL
Research Year
2019

Tunable ternary nanocomposite prepared by electrodeposition for biosensing of centrally acting reversible acetyl cholinesterase inhibitor donepezil hydrochloride in real samples

Research Abstract
This paper describes the decoration of pencil graphite electrode (PGE) with a thin film of solochrome black T (SBT) and N-doped carbon nanodots (N-CNDs)/ cobalt nanoparticles (CoNPs) to amplify signal of the measurement. This nanocomposite was chosen to enhance surface activity and electron transfer toward donepezil HCl (DZ HCl) oxidation. The physical properties of nanocomposite were characterized by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), electron impedance spectroscopy (ESI) and energy dispersive X-ray (EDX) spectroscopy. Cyclic voltammetry was utilized to quantify DZ HCl at the modified PGE in Britton-Robinson buffer (pH = 6.5). Under optimized experimental conditions, peak current increased with the increase in the concentration of DZ HCl and was linear between the range of 1.5 nM–400 μM with a relatively low detection limit of 0.0005 μM. Due to high sensitivity, simplicity and cost-effectiveness of the designated sensor; it was used as a simple method for detecting DZ HCl in rabbit plasma and during its pharmacokinetic study.
Research Authors
Fardous A.Mohamed, Pakinaz Y.Khashabaa, Reem Y.Shahin, Mohamed M.El-Wekil
Research Journal

Colloids and Surfaces A: Physicochemical and Engineering Aspects
Research Publisher
Elsevier
Research Rank
1
Research Vol
567
Research Website
NULL
Research Year
2019

Tunable ternary nanocomposite prepared by electrodeposition for biosensing of centrally acting reversible acetyl cholinesterase inhibitor donepezil hydrochloride in real samples

Research Abstract
This paper describes the decoration of pencil graphite electrode (PGE) with a thin film of solochrome black T (SBT) and N-doped carbon nanodots (N-CNDs)/ cobalt nanoparticles (CoNPs) to amplify signal of the measurement. This nanocomposite was chosen to enhance surface activity and electron transfer toward donepezil HCl (DZ HCl) oxidation. The physical properties of nanocomposite were characterized by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), electron impedance spectroscopy (ESI) and energy dispersive X-ray (EDX) spectroscopy. Cyclic voltammetry was utilized to quantify DZ HCl at the modified PGE in Britton-Robinson buffer (pH = 6.5). Under optimized experimental conditions, peak current increased with the increase in the concentration of DZ HCl and was linear between the range of 1.5 nM–400 μM with a relatively low detection limit of 0.0005 μM. Due to high sensitivity, simplicity and cost-effectiveness of the designated sensor; it was used as a simple method for detecting DZ HCl in rabbit plasma and during its pharmacokinetic study.
Research Authors
Fardous A.Mohamed, Pakinaz Y.Khashabaa, Reem Y.Shahin, Mohamed M.El-Wekil
Research Journal

Colloids and Surfaces A: Physicochemical and Engineering Aspects
Research Publisher
Elsevier
Research Rank
1
Research Vol
567
Research Website
NULL
Research Year
2019

Tunable ternary nanocomposite prepared by electrodeposition for biosensing of centrally acting reversible acetyl cholinesterase inhibitor donepezil hydrochloride in real samples

Research Abstract
This paper describes the decoration of pencil graphite electrode (PGE) with a thin film of solochrome black T (SBT) and N-doped carbon nanodots (N-CNDs)/ cobalt nanoparticles (CoNPs) to amplify signal of the measurement. This nanocomposite was chosen to enhance surface activity and electron transfer toward donepezil HCl (DZ HCl) oxidation. The physical properties of nanocomposite were characterized by scanning electron microscope (SEM), Fourier transform infrared spectroscopy (FTIR), electron impedance spectroscopy (ESI) and energy dispersive X-ray (EDX) spectroscopy. Cyclic voltammetry was utilized to quantify DZ HCl at the modified PGE in Britton-Robinson buffer (pH = 6.5). Under optimized experimental conditions, peak current increased with the increase in the concentration of DZ HCl and was linear between the range of 1.5 nM–400 μM with a relatively low detection limit of 0.0005 μM. Due to high sensitivity, simplicity and cost-effectiveness of the designated sensor; it was used as a simple method for detecting DZ HCl in rabbit plasma and during its pharmacokinetic study.
Research Authors
Fardous A.Mohamed, Pakinaz Y.Khashabaa, Reem Y.Shahin, Mohamed M.El-Wekil
Research Journal

Colloids and Surfaces A: Physicochemical and Engineering Aspects
Research Publisher
Elsevier
Research Rank
1
Research Vol
567
Research Website
NULL
Research Year
2019

Dual-Wavelength Thin-Layer Chromatographic-Densitometric Determination of Febuxostat in Combination with Acetaminophen in Synthetic Mixture and in Pharmaceutical Formulations

Research Abstract
The combination of xanthine oxidase inhibitor febuxostat (FBX) with acetaminophen (ACE) is widely used in the treatment of gout. A rapid, simple, selective, and precise densitometric method was developed and validated for the simultaneous estimation of FBX–ACE mixture in a synthetic binary mixture and in their pharmaceutical dosage forms. The method employed thin-layer chromatography (TLC) aluminum plates precoated with silica gel G 60 F254 as the stationary phase using chloroform-methanol-cyclohexane-acetic acid 96% (7:1:1:0.1, v/v) as the mobile phase. The optimized mobile phase selected for development gave compact bands (Rf values were 0.65 and 0.46 for FBX and ACE, respectively). Spectrodensitometric scanning integration was performed using dual-wavelength detection at 320 and 250 nm for FBX and ACE, respectively. The linear regression data for the calibration plots showed excellent linear relationship (r = 0.9997 and 0.9992 for FBX and ACE, respectively). The method was validated for precision, accuracy, robustness, and recovery. The limits of detection and quantification were calculated. The statistical analysis proved that the method is reproducible and selective for the estimation of this binary mixture.
Research Authors
Samia M. El-Gizawy, Noha N. Atia, Noha M. Hosny
Research Journal
Journal of Planar Chromatography, DOI: 10.1556/1006.2017.30.6.5
Research Member
Research Publisher
NULL
Research Rank
1
Research Vol
Vol. 30, No. 6
Research Website
NULL
Research Year
2017
Subscribe to